Product / Spectroscopy

Standard rectangular fluorometer cells, Type 3, are the most popular cells for general fluorescence measurement; all four windows and the bottom are polished. The smaller volume Types 9F, 17F and 18F are identical to the Type 9 semi-micro, Type 17 short micro and Type 18 micro ranges except that all walls and the base are polished. Spectrosil quartz is recommended for fluorescence because it has no background fluorescence. Unless specifically designed otherwise, all cells are assembled by fully fused construction without intermediate adhesives and can generally be used with pressure differentials of up to three atmospheres. Standard window thickness is 1.25 mm and the standard path length tolerance is ±0.01 mm (catalog general specifications).

Manufacturer website (opens in a new tab)

Source: manufacturer website (opens in a new tab) · Image: manufacturer website

Order codes and options

16 codes

Fluorometer cells: standard, semi-micro and micro (Types 3, 9F, 18F, 17F) order codes and properties
CodeWindow materialPath lengthNominal volumeQuote list
3-G-5Optical glass (334-2500 nm)5 mm1.7 mL
3-G-10Optical glass (334-2500 nm)10 mm3.5 mL
3-G-20Optical glass (334-2500 nm)20 mm7 mL
3-G-40Optical glass (334-2500 nm)40 mm14 mL
3-SOG-10Special optical glass (320-2500 nm)10 mm3.5 mL
3-Q-5Spectrosil quartz (far UV) (170-2700 nm)5 mm1.7 mL
3-Q-10Spectrosil quartz (far UV) (170-2700 nm)10 mm3.5 mL
3-Q-20Spectrosil quartz (far UV) (170-2700 nm)20 mm7 mL
3-Q-40Spectrosil quartz (far UV) (170-2700 nm)40 mm14 mL
3-I-5Infrasil quartz (near IR) (220-3800 nm)5 mm1.7 mL
3-I-10Infrasil quartz (near IR) (220-3800 nm)10 mm3.5 mL
3-I-20Infrasil quartz (near IR) (220-3800 nm)20 mm7 mL
3-I-40Infrasil quartz (near IR) (220-3800 nm)40 mm14 mL
9F-Q-10Spectrosil quartz (far UV) (170-2700 nm)10 mm1.4 mL
17F-Q-10Spectrosil quartz (far UV) (170-2700 nm)10 mm0.4 mL
18F-Q-10Spectrosil quartz (far UV) (170-2700 nm)10 mm0.7 mL

Technical specifications

Fluorometer cells: standard, semi-micro and micro (Types 3, 9F, 18F, 17F) technical specifications
Window materialsOptical glass, Special optical glass, Spectrosil quartz, Infrasil quartz
Path length range (mm)5 - 40 mm
Nominal volume range (mL)0.4 - 14
Number of variants16

Source: starnacells.com (opens in a new tab) · Starna Cells 2026 Catalog, p. 26 (dimension table) · starnacells.com (opens in a new tab) · starnacells.com product type page. Values come from the manufacturer and are confirmed at the quotation stage.